Portable Emergency and Transport Ventilator AJ-2202

FOB Reference Price:Get Latest Price
US $1,000-2,000 / Units | 1 Unit/Units (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Type:
Respiratory Equipments Accessories
Brand Name:
ANJUE MEDICAL
Model Number:
AJ-2202
Place of Origin:
China (Mainland)
Power:
AC220V+22V 50HZ+1HZ
Tidal volume:
50-1500 mL
Rate:
1-99bpm
SIMVrate:
2-20bpm
I:E:
4:1-1:8
Trigger sensitivity:
-1.0-1.0kPa
PEEP:
0-25cmH2O
Pressure control:
3-50cmH2O
Inspiratory platform:
0-50%
Oxygen concentration:
48%-100%
Supply Ability
Supply Ability:
1000 Unit/Units per Month
Packaging & Delivery
Packaging Details
standard package for the international transporation
0.14CBM, 12KG
Port
Shanghai/ Shenzhen
Lead Time :
within 10 days upon receipt of payment

Specifications

1.Emergency and Transport Ventilator
2.Power :AC 220V 10% 50Hz 1Hz ,UPS, Storage battery
3.Battery under voltage alarm

 

Portable Emergency and Transport Ventilator AJ-2202

 

 

1.jpg 

 

 

Main technical parameters ----  Emergency and Transport Ventilator  

 

Display  

Colored LCD, touch screen setting, big font display, free changeable angles of views

Various ventilation modes

SIPPV,SIMV,PCV,SPONT,MANUAL,CPAP

Ventilation parameters

PEEP,SIGH,IRV,Inspiratory platform

Tidal Volume

50-1500 mL

Rate

1~99bpm

SIMVrate

2~20bpm

I:E

4:1~1:8

Trigger sensitivity

-1.0~1.0kPa

PEEP

0~25cmH2O

SIGH

1.5 times the inspiratory time (60 ~ 120 times adjustable)

Inspiratory platform

0~50%

Oxygen concentration

48%~100%

Pressure limit

5~60cmH2O

  

Parameters for ventilation monitoring     tidal volume, ventilation volume, IPPV rate, total respiratory rate, peak pressure of airway, pressure - time waveform, flow rate - time waveform, inspiratory trigger pressure, Inspiratory platform, Oxygen concentration, battery capacity

Safety alarm system  

Airway pressure alarm                 upper limit setting range   0.3~6.0 kPa

lower limit setting range   0.2~5.0 kPa

Per-minute ventilation volume alarm     upper limit setting range 3.0~30L/min

lower limit setting range 1.0~10L/min

Vt alarm                            upper limit setting range 10~2000ml  

lower limit setting range 0~1800 ml    

Sustained high-pressure alarm     it will give alarm when stress have consistently been higher than 2.5 kPa                                                  

Suffocation alarm                 it will give sound and light alarm if there is no tidal volume input for 15 seconds    

Power failure alarm    

Power                           AC 220V±10%     50Hz±1Hz

                               UPS, Storage battery

Battery under-voltage alarm  

Power loss alarm    

Intubation off alarm  

 

 